D000140-001 D QLogic 12000 SeriesInfiniBand Switches and DirectorsHardware Installation GuideVersion 6.0

Page 2 - Document Revision History

PrefaceTechnical Supportx D000140-001 DKnowledge DatabaseThe QLogic knowledge database is an extensive collection of QLogic product information that

Page 3 - Table of Contents

A–QLogic 12000 Series Product Specifications12800 SeriesA-10 D000140-001 DNotes

Page 4 - Hardware Installation Guide

D000140-001 D B-1B Safety and Regulatory Compliance InformationThis section provides regulatory compliance, safety and electromagnetic compatibility (

Page 5

Safety and Regulatory Compliance InformationSafety InformationB-2 D000140-001 DDichiarazione 1:Scollegare il dispositivo - L'unità potrebbe avere

Page 6

Safety and Regulatory Compliance InformationSafety InformationD000140-001 D B-3Statement 2:Chassis Lifting - Use safe practices when lifting. Verklari

Page 7 - Documentation Conventions

Safety and Regulatory Compliance InformationSafety InformationB-4 D000140-001 DNOTA: utilizzare un gruppo di persone adeguato al peso di ogni prodotto

Page 8 - cd /root and press ENTER

Safety and Regulatory Compliance InformationSafety InformationD000140-001 D B-5声明 2:提起机箱 - 提起机箱时请采取安全措施。注: 请按照每个具体产品的重量来使用一定的人数,并遵照适当的说明。可能的话,使用机械起重器。

Page 9 - Technical Support

Safety and Regulatory Compliance InformationSafety InformationB-6 D000140-001 DStatement 3:Energy Hazard - To reduce risk of electric shock, keep hand

Page 10 - Knowledge Database

Safety and Regulatory Compliance InformationSafety InformationD000140-001 D B-7Uttalande 3:Risk för elektrisk stöt. Reducera risken för elektrisk stöt

Page 11 - 1 Installation

Safety and Regulatory Compliance InformationSafety InformationB-8 D000140-001 DStatement 4:Laser Radiation - certain optical products may emit laser r

Page 12 - Cable Requirements

Safety and Regulatory Compliance InformationSafety InformationD000140-001 D B-9Declaração 4:Radiação laser - Certos produtos ópticos podem emitir radi

Page 13

D000140-001 D 1-11 InstallationThis section describes how to install and configure for first-time use: The QLogic 12000 switches in a network envi

Page 14 - Uninterruptible Power Supply

Safety and Regulatory Compliance InformationSafety InformationB-10 D000140-001 DStatement 5:No User Serviceable parts - Hazardous energy levels may be

Page 15 - Installation Tasks Checklist

Safety and Regulatory Compliance InformationSafety InformationD000140-001 D B-11Uttalande 5:Inga delar kan underhållas av användaren. Farliga energini

Page 16 - Mark the Rack

Safety and Regulatory Compliance InformationSafety InformationB-12 D000140-001 DStatement 6:Equipment Installation - Only qualified personnel should b

Page 17 - 12200/12300 Installation

Safety and Regulatory Compliance InformationSafety InformationD000140-001 D B-13Kijelentés 6:Berendezés telepítése – Kizárólag szakképzett személyzet

Page 18 - 1-8 D000140-001 D

Safety and Regulatory Compliance InformationSafety InformationB-14 D000140-001 DStatement 7:Adding or Replacing Modules - These modules are intended o

Page 19 - D000140-001 D 1-9

Safety and Regulatory Compliance InformationSafety InformationD000140-001 D B-15Erklæring 7:Tillegging eller utskifting av moduler - disse modulene sk

Page 20 - Figure 1-6. 12200 Hat Rails

Safety and Regulatory Compliance InformationSafety InformationB-16 D000140-001 Dステートメント 7:モジュールの追加または取替え - これらのモジュールは QLogic 12000 シリーズ MPFD ベースユニットへの

Page 21 - D000140-001 D 1-11

Safety and Regulatory Compliance InformationSafety InformationD000140-001 D B-17

Page 22 - 12800-040 Installation

Safety and Regulatory Compliance InformationSafety InformationB-18 D000140-001 DNotes

Page 23 - Installation Tasks

D000140-001 D C-1C Serial Port PinoutsFor those users making their own serial cables, follow the guidelines below.Figure C-1 Serial Port Pinouts

Page 24 - 1-14 D000140-001 D

1–InstallationPlanning the Installation1-2 D000140-001 DCable RequirementsCable DistancesWhen planning the location of the switches, consider the di

Page 25 - D000140-001 D 1-15

Serial Port PinoutsC-2 D000140-001 DFigure C-1 represents the RJ-11 connector located on the QLogic 12200 and12300. The only serial port signals re

Page 26 - 12800-120 Installation

Serial Port PinoutsD000140-001 D C-3

Page 27 - D000140-001 D 1-17

Serial Port PinoutsC-4 D000140-001 DNotes

Page 28 - 1-18 D000140-001 D

D000140-001 D D-1D FRU ReplacementThis section details replacement information for various QLogic 12000 field replaceable units (FRUs). For replace

Page 29 - D000140-001 D 1-19

D–FRU ReplacementQLogic 12300D-2 D000140-001 D3. Remove the switch from the rack. Keep all rail hardware installed in the rack.4. Remove the hat rai

Page 30 - 1-20 D000140-001 D

D–FRU ReplacementQLogic 12300D000140-001 D D-3Fan/Power Supply ReplacementFRU part number:12300-PS01Removal Procedures1. Push the finger tab to the

Page 31 - D000140-001 D 1-21

D–FRU ReplacementQLogic 12800 SeriesD-4 D000140-001 DQLogic 12800 SeriesFan ReplacementFRU part numbers: Intake Fan: 12800-FITK Exhaust Fan: 12800

Page 32 - 1-22 D000140-001 D

D–FRU ReplacementQLogic 12800 SeriesD000140-001 D D-5Figure D-3 .12800 Intake and Exhaust FansReplacement Procedures1. Slide the fan tray straight

Page 33 - D000140-001 D 1-23

D–FRU ReplacementQLogic 12800 SeriesD-6 D000140-001 DPower Supply ReplacementFRU part number:12800-PS01Removal Procedures1. Push the release latch t

Page 34 - 12800-180 Installation

D–FRU ReplacementQLogic 12800 SeriesD000140-001 D D-7Leaf Module ReplacementFRU part number: 18 Port Leaf: 12800-LF18 24 Port Leaf: 12800-LF24Rem

Page 35 - D000140-001 D 1-25

1–InstallationPlanning the InstallationD000140-001 D 1-3Cable Handling and Bend RadiusProvide proper strain relief by adhering to the following gui

Page 36 - 1-26 D000140-001 D

D–FRU ReplacementQLogic 12800 SeriesD-8 D000140-001 D1. Pull the release arms down until the leaf module disengages from the backplane connector.Fig

Page 37 - D000140-001 D 1-27

D–FRU ReplacementQLogic 12800 SeriesD000140-001 D D-9Spine Module ReplacementFRU part number: Single Spine Module: 12800-SPSG01 Double Spine Modu

Page 38 - 1-28 D000140-001 D

D–FRU ReplacementQLogic 12800 SeriesD-10 D000140-001 DManagement Module ReplacementFRU part number:12800-MM01Removal Procedures1. Loosen the thumbsc

Page 40 - 1-30 D000140-001 D

© 2010 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic and the QLogic logo are registe

Page 41 - D000140-001 D 1-31

1–InstallationPlanning the Installation1-4 D000140-001 DFigure 1-2. Fiber Optic Bend RadiusUninterruptible Power SupplyConsider the following when s

Page 42 - 12800-360 Installation

1–InstallationInstallation Tasks ChecklistD000140-001 D 1-5 Whether or not the UPS unit also provides online protection.Installation Tasks Checkli

Page 43 - D000140-001 D 1-33

1–InstallationInstallation Tasks Checklist1-6 D000140-001 D The ambient temperature stays between 50° - 113°F (5° - 40° C). Cabinet doors do not i

Page 44 - 1-34 D000140-001 D

1–Installation12200/12300 InstallationD000140-001 D 1-712200/12300 InstallationThis section describes the rack mounting instructions for the 12200

Page 45

1–Installation12200/12300 Installation1-8 D000140-001 D2. Install eight (8) cage nuts into rack posts, two (2) cage nuts per post. Install the mount

Page 46 - 1-36 D000140-001 D

1–Installation12200/12300 InstallationD000140-001 D 1-9Figure 1-5. 12200 and 12300 Four Post Standard Rack Mounting12200 Four Post Shallow-Depth Ra

Page 47 - D000140-001 D 1-37

Page ii D000140-001 DQLogic 12000 Series InfiniBand Switches and DirectorsHardware Installation GuideInformation furnished in this manual is believ

Page 48 - 1-38 D000140-001 D

1–Installation12200/12300 Installation1-10 D000140-001 DInstallation1. Install the hat rails with mounting ears towards the port side of the switch.

Page 49 - D000140-001 D 1-39

1–Installation12200/12300 InstallationD000140-001 D 1-11Figure 1-7. 12200 Four Post Shallow Rack Mounting

Page 50 - 1-40 D000140-001 D

1–Installation12800-040 Installation1-12 D000140-001 D12800-040 InstallationMounting Hardware Kit Contents Support Rails HAT Brackets C-Brackets

Page 51 - D000140-001 D 1-41

1–Installation12800-040 InstallationD000140-001 D 1-13Installation Tasks1. Install the clip nuts. Install M6 clip nuts in the following locations o

Page 52 - 1-42 D000140-001 D

1–Installation12800-040 Installation1-14 D000140-001 DFigure 1-10. Support Rail Installation3. Orient the chassis such that mounting flanges are in

Page 53 - D000140-001 D 1-43

1–Installation12800-040 InstallationD000140-001 D 1-15Figure 1-11. Rack Installation5. If applicable, replace the door(s) on the rack.

Page 54 - 1-44 D000140-001 D

1–Installation12800-120 Installation1-16 D000140-001 D12800-120 InstallationMounting Hardware Kit Contents: Support Rails HAT Brackets C-Brackets

Page 55 - D000140-001 D 1-45

1–Installation12800-120 InstallationD000140-001 D 1-17Figure 1-12. Clip Nut Installation LocationsFor improved stability, orient the clip nuts as s

Page 56 - 1-46 D000140-001 D

1–Installation12800-120 Installation1-18 D000140-001 D3. Install support rails in the rack. Fasten with two (2) M6 screws per EIA rail to pre-instal

Page 57 - Connecting Power

1–Installation12800-120 InstallationD000140-001 D 1-19Figure 1-15. Hat Bracket Installation5. Orient the chassis such that mounting flanges are in

Page 58 - Figure 1-41. DC ON/OFF Switch

D000140-001 D iiiTable of ContentsPrefaceIntended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 59 - Guidelines

1–Installation12800-120 Installation1-20 D000140-001 DFigure 1-16. Mounting Flange Installation6. Fasten the chassis to the rack with eight (8) M6 s

Page 60 - User Site Installation

1–Installation12800-120 InstallationD000140-001 D 1-21Figure 1-17. Chassis Installation7. Slide two (2) C-brackets over the Hat brackets that are p

Page 61 - Start-up Procedures

1–Installation12800-120 Installation1-22 D000140-001 DFigure 1-18. C Bracket Installation8. If applicable, install the optional cable management gui

Page 62 - 1-52 D000140-001 D

1–Installation12800-120 InstallationD000140-001 D 1-23Figure 1-19. Cable Management Installation9. If applicable, replace the door(s) on the rack.

Page 63 - D000140-001 D 1-53

1–Installation12800-180 Installation1-24 D000140-001 D12800-180 InstallationMounting Hardware Kit Contents: Support Rails HAT Brackets C-Brackets

Page 64 - 1-54 D000140-001 D

1–Installation12800-180 InstallationD000140-001 D 1-25Figure 1-20. Clip Nut LocationsFor improved stability, orient the clip nuts as shown (i.e., o

Page 65 - Enabling 8X Ports

1–Installation12800-180 Installation1-26 D000140-001 D3. Install support rails in the rack. Fasten with two (2) M6 screws per EIA rail to pre-instal

Page 66 - Figure 1-49. 8X Ports Enabled

1–Installation12800-180 InstallationD000140-001 D 1-27Figure 1-23. Flat Bracket Installation5. Orient the chassis such that mounting flanges are in

Page 67 - D000140-001 D 1-57

1–Installation12800-180 Installation1-28 D000140-001 D6. Fasten the mounting flanges using M6 screws to the clip nuts that are pre-installed in the

Page 68 - 1-58 D000140-001 D

1–Installation12800-180 InstallationD000140-001 D 1-29Figure 1-24. Mounting Flange Installation7. Slide four (4) C-brackets over the HAT brackets t

Page 69 - Figure 1-52. 8X Ports Enabled

iv D000140-001 DQLogic 12000 Series InfiniBand Switches and DirectorsHardware Installation GuideSelecting a Rack . . . . . . . . . . . . . . . . . .

Page 70 - 1-60 D000140-001 D

1–Installation12800-180 Installation1-30 D000140-001 DFigure 1-25. U Bracket Installation8. If applicable, install the optional cable management gui

Page 71 - Component LEDs

1–Installation12800-180 InstallationD000140-001 D 1-31Figure 1-26. Cable Management Guide Installation9. If applicable, replace the door(s) on the

Page 72 - MRL Active

1–Installation12800-360 Installation1-32 D000140-001 D12800-360 InstallationMounting Hardware Kit Contents: Mounting Kit containing: Support Shelf

Page 73 - Figure 1-55. MRL Active LED

1–Installation12800-360 InstallationD000140-001 D 1-33Figure 1-27. 12800-360 Front and Rear Cabling

Page 74 - Leaf Module

1–Installation12800-360 Installation1-34 D000140-001 DLocating Rack Mounting Posts for Front and Back Cable RoutingIn a typical rack, front EIA rail

Page 75 - Spine Module

1–Installation12800-360 InstallationD000140-001 D 1-35Installation Tasks1. Install clip nuts: If applicable, remove the doors of the rack. Install

Page 76 - SEEB Module

1–Installation12800-360 Installation1-36 D000140-001 DFigure 1-30. Clip Nut Orientation2. Attach four (4) mounting brackets to the support shelf as

Page 77 - 12200 and 12300

1–Installation12800-360 InstallationD000140-001 D 1-37Figure 1-31. Support Shelf Assembly4. Install the support shelf into the rack. Fasten the M6

Page 78 - 12800 Fans and Power Supplies

1–Installation12800-360 Installation1-38 D000140-001 DFigure 1-32. Attaching the Support Shelf to the Rack5. Orient and position the chassis for ins

Page 79 - Power Supply LEDs

1–Installation12800-360 InstallationD000140-001 D 1-396. Orientation of the chassis on a pallet: The chassis has been packaged on sliding surfaces

Page 80 - 1-70 D000140-001 D

D000140-001 D vQLogic 12000 Series InfiniBand Switches and DirectorsHardware Installation Guide12200 and 12300. . . . . . . . . . . . . . . . . .

Page 81 - Procedures

1–Installation12800-360 Installation1-40 D000140-001 DFigure 1-33. Loading from the Pallet7. Position the chassis on front on the rack. Use pallet j

Page 82 - 1-72 D000140-001 D

1–Installation12800-360 InstallationD000140-001 D 1-41Figure 1-34. Positioning the Switch8. Installing the chassis in the rack: Align the chassis w

Page 83 - D000140-001 D 1-73

1–Installation12800-360 Installation1-42 D000140-001 DFigure 1-35. Sliding the Switch off the Pallet9. Fasten the front of the chassis to the rack b

Page 84 - 1-74 D000140-001 D

1–Installation12800-360 InstallationD000140-001 D 1-43Figure 1-36. Fasten the Chassis to the Front of the Rack10. Fasten the rear of the chassis to

Page 85 - D000140-001 D 1-75

1–Installation12800-360 Installation1-44 D000140-001 DFigure 1-37. Fasten the Chassis to the Back of the Rack

Page 86 - 1-76 D000140-001 D

1–Installation12800-360 InstallationD000140-001 D 1-4512. Attach the cable management guides. If applicable, attach the cable management guides to

Page 87 - D000140-001 D 1-77

1–InstallationConnect Equipment to the Ports and Power On the System1-46 D000140-001 DConnect Equipment to the Ports and Power On the SystemFigure 1

Page 88 - QLogic 12000 Six-Port Upgrade

1–InstallationConnect Equipment to the Ports and Power On the SystemD000140-001 D 1-471. Connect a Category 5 or 6 (Cat 5/6) Ethernet cable to the

Page 89

1–InstallationConnect Equipment to the Ports and Power On the System1-48 D000140-001 DFigure 1-41. DC ON/OFF Switch5. The switch, power supply, and

Page 90 - 1-80 D000140-001 D

1–InstallationBringing Up the System For the First TimeD000140-001 D 1-49Bringing Up the System For the First Time12800-Series Management Module Pr

Page 91 - A QLogic 12000 Series

vi D000140-001 DQLogic 12000 Series InfiniBand Switches and DirectorsHardware Installation GuideQLogic 12300. . . . . . . . . . . . . . . . . . . .

Page 92 - Environmental Specifications

1–InstallationBringing Up the System For the First Time1-50 D000140-001 DFigure 1-44. MRL Protective Label 33. After testing is complete at the stag

Page 93

1–InstallationBringing Up the System For the First TimeD000140-001 D 1-512. Peel off the protective label. Re-engage the lever and tighten the thum

Page 94 - Power Specifications

1–InstallationBringing Up the System For the First Time1-52 D000140-001 DChanging the Switch IP Address and Default Gateway via the CLIThe command l

Page 95

1–InstallationBringing Up the System For the First TimeD000140-001 D 1-53Welcome to the <SWITCH> CLI. Type 'list' for the list of c

Page 96 - Power Distribution Guidelines

1–InstallationBringing Up the System For the First Time1-54 D000140-001 D Management Module 227: 192.168.100.10 Management Module 228: 192.168.100

Page 97 - Table A-4. AC Plug Types

1–InstallationBringing Up the System For the First TimeD000140-001 D 1-55Enabling 8X PortsUsers can enable 8X (10 Gbps) ports by combining two (2)

Page 98

1–InstallationBringing Up the System For the First Time1-56 D000140-001 D4. At the switch, unplug and reinsert the cables to the physical ports. Aft

Page 99 - D000140-001 D A-9

1–InstallationBringing Up the System For the First TimeD000140-001 D 1-57Figure 1-50. 8X Port StatisticsThe first port of the group (port 10) is sh

Page 100 - A-10 D000140-001 D

1–InstallationBringing Up the System For the First Time1-58 D000140-001 DCreating an 8x Port: 12800 SeriesFor the 12800 switches, 8x DUOs are set up

Page 101 - B Safety and Regulatory

1–InstallationBringing Up the System For the First TimeD000140-001 D 1-595. After reinserting the cables, bring up Chassis Viewer. The 8X ports are

Page 102 - B-2 D000140-001 D

D000140-001 D viiPrefaceThis manual describes the hardware installation and initial configuration tasks for the QLogic 12000 series that includes:

Page 103 - Statement 2:

1–InstallationBringing Up the System For the First Time1-60 D000140-001 DFigure 1-53. 8X Port StatisticsThe first port of the group (port 8) is show

Page 104 - B-4 D000140-001 D

1–InstallationComponent LEDsD000140-001 D 1-61Component LEDsManagement ModuleFigure 1-54. Management Module LEDsModule StatusThe status LED indicat

Page 105 - ステートメント 2:

1–InstallationComponent LEDs1-62 D000140-001 D The module is not removable.Chassis Status and AttentionThe chassis status LED is Green when the sys

Page 106 - Statement 3:

1–InstallationComponent LEDsD000140-001 D 1-63Figure 1-55. MRL Active LED

Page 107 - ステートメント 3:

1–InstallationComponent LEDs1-64 D000140-001 DLeaf ModuleFigure 1-56. Leaf Module LEDsIB Port LEDsEach module IB port has a Green IB link status LED

Page 108 - Statement 4:

1–InstallationComponent LEDsD000140-001 D 1-65 Off - the system functioning normally. Steady Amber - the system requires some attention, which co

Page 109 - D000140-001 D B-9

1–InstallationComponent LEDs1-66 D000140-001 D The switch temperature is at a warning level on the module. The switch silicon temperature is at a

Page 110 - Statement 5:

1–InstallationComponent LEDsD000140-001 D 1-6712200 and 12300Figure 1-59. 12200 and 12300LEDsIB Port LEDsEach module IB port has a Green IB link st

Page 111 - ステートメント 5:

1–InstallationComponent LEDs1-68 D000140-001 D DC voltages on the board are slightly out of tolerance (12V Bulk, 5V, 3.3V and 1.8V are all monitore

Page 112 - Statement 6:

1–InstallationComponent LEDsD000140-001 D 1-69 A single fan failure when the rotation speed is less than 4000 RPM or greater than 10950 RPM. Gree

Page 113 - ステートメント 6:

PrefaceDocumentation Conventionsviii D000140-001 D CAUTION! indicates the presence of a hazard that has the potential of causing damage to data or

Page 114 - Statement 7:

1–InstallationSwitch-Based QLogic Fabric Manager License Key1-70 D000140-001 DSwitch-Based QLogic Fabric Manager License KeyIf purchased, certain pa

Page 115 - D000140-001 D B-15

1–InstallationSwitch-Based QLogic Fabric Manager License KeyD000140-001 D 1-71Procedures1. Record the IFS serial number.2. Go to the QLogic Feature

Page 116 - ステートメント 7:

1–InstallationSwitch-Based QLogic Fabric Manager License Key1-72 D000140-001 D4. Click Activate License Key and click Continue. The following screen

Page 117 - D000140-001 D B-17

1–InstallationSwitch-Based QLogic Fabric Manager License KeyD000140-001 D 1-73Figure 1-66. License Key Activation Center 46. Enter all applicable i

Page 118 - B-18 D000140-001 D

1–InstallationSwitch-Based QLogic Fabric Manager License Key1-74 D000140-001 DFigure 1-67. License Key Activation Center 57. In the City: and Zip: t

Page 119 - C Serial Port Pinouts

1–InstallationSwitch-Based QLogic Fabric Manager License KeyD000140-001 D 1-75Figure 1-69. License Key Activation Center 79. Click Continue. The fo

Page 120 - P4-Tx P3 P5-Rx

1–InstallationSwitch-Based QLogic Fabric Manager License Key1-76 D000140-001 DFigure 1-70. License Key Activation Center 810. In the GUID: text box,

Page 121 - D000140-001 D C-3

1–InstallationSwitch-Based QLogic Fabric Manager License KeyD000140-001 D 1-77NOTE:The FRU GUID can be found: On the label of each FRU. Using the

Page 122 - C-4 D000140-001 D

1–InstallationQLogic 12000 Six-Port Upgrade1-78 D000140-001 DQLogic 12000 Six-Port UpgradeUsers can order a six-port License Key upgrade for the QLo

Page 123 - D FRU Replacement

1–InstallationQLogic 12000 Six-Port UpgradeD000140-001 D 1-79Procedures1. Record the 12300-BS18 serial number.2. Go to the QLogic Feature Activatio

Page 124 - QLogic 12300

PrefaceLicense AgreementsD000140-001 D ixLicense AgreementsRefer to the QLogic Software End User License Agreement for a complete listing of all li

Page 125 - Fan/Power Supply Replacement

1–InstallationQLogic 12000 Six-Port Upgrade1-80 D000140-001 D

Page 126 - QLogic 12800 Series

D000140-001 D A-1A QLogic 12000 SeriesProduct SpecificationsPhysical SpecificationsAll products within the 12200, 12300 and 12800 Director series a

Page 127 - Replacement Procedures

A–QLogic 12000 Series Product SpecificationsEnvironmental SpecificationsA-2 D000140-001 DEnvironmental Specifications Operating temperature: 5°–40

Page 128 - Power Supply Replacement

A–QLogic 12000 Series Product Specifications12800 SeriesD000140-001 D A-312800 SeriesAll 12800 series switches use the same fan tray modules -- int

Page 129 - Leaf Module Replacement

A–QLogic 12000 Series Product Specifications12800 SeriesA-4 D000140-001 D Temperatures of all major heat producing components are continuously moni

Page 130

A–QLogic 12000 Series Product Specifications12800 SeriesD000140-001 D A-5Maximum output per supply1200 WattsInput voltage 90-264 VAC autorangingInp

Page 131 - Spine Module Replacement

A–QLogic 12000 Series Product Specifications12800 SeriesA-6 D000140-001 DPower Distribution GuidelinesThe following section details power distributi

Page 132 - Management Module Replacement

A–QLogic 12000 Series Product Specifications12800 SeriesD000140-001 D A-7Figure A-1. 12800-Series Power DistributionTable A-4. AC Plug TypesRegion/

Page 133

A–QLogic 12000 Series Product Specifications12800 SeriesA-8 D000140-001 DEurope (Schuko) 200-240 CEE 7/7 Used in Austria, Belgium, Finland, France,

Page 134

A–QLogic 12000 Series Product Specifications12800 SeriesD000140-001 D A-9