50 Sun StorageTek 6140 Array Release Notes November 2008
Preparing the Telco Rack
Install the rack as described in the installation instructions provided by the
manufacturer.
Note Sun Microsystems makes no warranties or guaranties as to fit, form, or
function of the Sun StorEdge 6140 array installed in third-party racks or cabinets. It
is the customer’s responsibility to ensure that the rack or cabinet can house the Sun
StorEdge 6140 array in all conditions that may exist. All racks and cabinets must
comply with local building and construction codes.
Populating a rack with trays starting from the bottom and moving up distributes the
weight correctly in the cabinet.
Attaching the Rails to a Telco 2-Post Rack
This procedure describes how to attach the rackmount rail kit to a Telco 2-post
frame. You can use rack rails with a depth of 3-to-6 inches.
You will mount each tray with its horizontal center aligned with the frame of the
Telco 2-post rack.
1. Loosely adjust the rail length to accommodate the length of the array.
1. Insert four (12-24 or 10-32) screws (one in each post side) in the front and back
mounting holes of the right and left posts (
FIGURE C-1). Do not tighten at this
time.
Use the lowest available mounting hole at the bottom of each post that can be
aligned with the top mount slot on the rail. The mount slot allows the rail to hang
over the screw. Make sure that all four screws are aligned and mounted at the
same height.