Qlogic QLogic Fibre Channel Switch Installation Guide Page 95

  • Download
  • Add to my manuals
  • Print
  • Page
    / 206
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 94
A – Specifications
Environmental
59055-00 B A-5
D
A.6
Environmental
Temperature
Operating ..................................
Non-operating ...........................
5 to 40°C (41 to 104°F)
-40 to 70°C (-40 to 158°F)
Humidity
Operating ..................................
Non-operating ...........................
15% to 80%, non-condensing
25% to 90%, non-condensing
Altitude
Operating ..................................
Non-operating ...........................
0 to 3048m (0 to 10,000 feet)
0 to 15,240m (0 to 50,000 feet)
Vibration
Operating ..................................
Non-operating ...........................
IEC 68-2
5-500 Hz, random, 0.21 G rms, 10 minutes
5-500 Hz, random, 2.09 G rms, 10 minutes
Shock
Operating ..................................
Non-operating ...........................
IEC 68-2
4 g, 11ms, 20 repetitions
30g, 292 ips, 3 repetitions, 3 axis
Air flow............................................ Front-to-back or back-to-front, by model
Page view 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 205 206

Comments to this Manuals

No comments